add wishlist add wishlist show wishlist add compare add compare show compare preloader
Cummins ISX SCR | 4329452, 4329453, A045R856, 045R856
Cummins ISX SCR | 4329452, 4329453, A045R856, 045R856
Cummins ISX SCR | 4329452, 4329453, A045R856, 045R856
Cummins ISX SCR | 4329452, 4329453, A045R856, 045R856
Sale

Cummins ISX SCR | 4329452, 4329453, A045R856, 045R856

SKU: SCRHDA-188085
$6,730.80
$5,822.93 In Stock Backordered

Lead Time:

Backordered

OR

Add to wishlist Added to wishlist
Add to compare Added to compare

Fast Shipping

Quality Parts

Best Pricing

  • Description
  • Shipping and Refund

OEM Replacement for Part #: 4329452, 4329453, A045R856, 045R856


Currently not for sale or installation in California.


Specifications

Brand
Dinex
Engine Manufacturer
Cummins
OEM Part Number
4329452, 4329453, A045R856, 045R856
Aftermarket Part Number(s)
58088
Product Dimensions
36.10 x 14.49 x 14.49 in
Weight
117.42 lb
Warranty
3 year unlimited mileage


Selective Catalytic Reduction (SCR)

 

The primary function of SCR catalyst in a diesel after-treatment systems (ATS) is to convert harmful nitrogen oxides (NOx =NO + NO2) in the exhaust gas to nitrogen and water. The SCR reaction takes place on the catalyst, in the presence of NH3 generated from AdBlue (Urea and water solution) upfront the SCR catalyst.

 

EPA advanced emissions regulations need above 95% NOx conversion levels and all Dinex SCR technologies achieve conversion levels well above this limit.

 

Dinex has a wide variety of SCR catalyst technologies which can be selected based on actual applications and ATS temperature levels. Typically, titanium-vanadium based technologies are suitable for applications, where the exhaust gas temperature is not exceeding 550 degrees C level. Cu-Zeolite and Fe-Zeolite technologies are suitable for conditions where the exhaust temperatures exceed well above 600 degrees C.

 

The most widely used SCR technology in advanced regulations is Cu-Zeolite based. The Dinex technology is typically characterized by high NOx conversion activity in wide temperature window, low NO2 formation, and very low NH3 oxidation, even at high temperature (optimal Urea utilization).


Dinex meets all levels of regulation

 

The Advanced US EPA07/10 regulations need complex after-treatment systems (ATS) to fulfill all regulatory requirements. After initial implementation in year 2007, US EPA regulations have been updated step by step over the years with primary focus on real driving emissions (RDE) and in-service conformity.

 

Dinex supports Heavy Duty and Medium Duty commercial vehicles with advanced catalyst coating technologies (DOC, DPF, SCR), which are among the best in class. The wide range of technologies provide the flexibility to modulate the ATS layout to the full benefit of our customers as per their duty cycle and application requirements. The catalyst technologies have been rigorously tested by major OEMs world-wide and meet the most stringent engineering targets and real driving emissions performance requirements.

 

With close to 30 years of experience in canning & housing as well as patented technologies for compact mixers, Dinex builds robust and flexible ATS canning to meet a variety of packaging and space requirements.


Return Policy

We offer many different shipping options from our brands. For any information for shipping, please review our Shipping Policy here: Shipping Policy - DPFSales



Return and Refund Policy

All returns are shipped at the customers expense, using the shipping method of your choice. We recommend marking any shipments as fragile and/or adding insurance to guarantee your item is returned safely. Please address all returns to the following -
 
Attn: Returns Processing
725 S. Lugo Avenue
San Bernardino, CA 92408

Returns will be accepted within 30 days from the original date of purchase only. Clearance items may not be returned. Items that are damaged, missing parts, dented, not in the original condition, or have obvious signs of use for reasons not due to DPFSales.com or seller error are subject to partial refunds or restocking fees of up to 50% of the item’s price. If an item is returned in excessively damaged and unusable condition, a refund will not be processed. If the buyer changes their mind about a purchase and returns an item in the original, like-new condition within the return window, the order is subject to a restocking fee up to 20% of the item’s price.


Once we have received your return, it will be inspected and processed. This process can take up to 7-10 business days. Based on the condition of the returned item(s), a 20% restocking fee, up to 50% may be deducted from your refund. We will notify you if no refund will be processed based on excessive damage and unusable condition. 


Refunds will be processed once all inspections have been completed. Refunds will be processed back to the original form of payment used for the purchase. Please allow 3-5 business days for the refund to appear on your account.

Recently Viewed